User GuideKSM137
27A3157 (Rev. 1)E2003, Shure IncorporatedTrademark Notices: The circular S logo, the stylized Shure logo, and the word“Shure” are registered trademar
SHURE INCORPORATEDKSM137 CARDIOID CONDENSER MICROPHONEIf you have any questions not answered in this booklet, please contact ShureApplications Enginee
2Low FrequencyResponse Switch0/15/25 dBAttenuation SwitchFIGURE 1. KSM137GENERAL DESCRIPTIONThe ShureR KSM137 is an end-address condenser microphone w
3PERFORMANCE CHARACTERISTICSS Extended frequency responseS Low self-noiseS Exceptional reproduction of low-frequency soundsS Can withstand high sound
4USING THE KSM137Mounting the MicrophoneTo secure the KSM137 to a floor stand or boom, thread the mount onto themicrophone stand and insert the microp
5Setting AttenuationThe attenuation switch on the KSM137 lets you reduce the signal level by up to 25 dBwithout altering frequency response. This can
6SPECIFICATIONSCartridge Type Permanently Biased CondenserFrequency Response 20–20,000 Hz (see Figure 3)Directional Polar Pattern Cardioid (see Figure
7FIGURE 3. TYPICAL FREQUENCY RESPONSE60 cmFIGURE 4. TYPICAL POLAR PATTERNS250 Hz1000 Hz2500 Hz10000 Hz500 Hz6400 Hz(0.8 IN)FIGURE 5. DIMENSIONS122 mm
8CERTIFICATIONEligible to bear CE Marking; conforms to European EMC directive 89/336/EEC.Meets applicable tests and performance criteria found in Euro