1
Safety
Technology
& Innovation
Feedback loop for monitoring downstream contactors or
expansion modules
Cyclical monitoring of the output contacts
Indication of the switching state via LED
2 start behaviors possible:
- monitored manual start
- automatic start
Short circuit and earth fault monitoring
Up to PL e, SILCL 3, category 4
Correct Use
SR10.AD is an emergency stop safety relay combination that
combines non-time-delayed and time-delayed contacts
in a very
compact housing. This permits dangerous components of a
system to be switched off quickly and safely in an emergency
situation. At the same time, other circuits can continue to be
supplied with voltage for up to 30 seconds to allow a tool to be
moved to its idle position or to brake following parts, for exam-
Features
4 positively driven safety relays contacts. Possible vari-
ants:
- 3 non-time-delayed and 1 time-delayed contact
- 2 non-time-delayed and
2 time-de
layed contact
- 1 non-time-delayed and 3 time-delayed contact
Continuously adjustable time delay (1 bis 30s)
Connection of:
- emergency stop buttons
- sa
fety switches
- non-contacts safety switches
- OSSD-Outputs
1- or 2-channel activation possible
Function
The moving parts of a machine or system can be quickly
and safely stopped in case of danger with the non-time-
delayed contacts of the SR10.AD.Safety contacts with time
-delay switch-off are also integrated into the
SR10.AD. They are used whenever it is safer to keep
supplying voltage to parts of a machine after the emer-
gency stop switch is operated.
It is ensured that a single fault or malfunction does not lead
to a loss of the safety function and that every fault is de-
tected by cyclical self-monitoring no later than when the
It is not allowed to open the device, tamper with the devi-
ce or bypass the safety devices.
All relevant safety regulations and standards are to be
observed.
The overall concept of the control system in which the
device is incorporated must be validated by the user.
Failure to observe the safety regulations can result in
death, serious injury and serious damage.
Installation
As per DIN EN 60204-1, the device is intended for installa-
tion in control cabinets with a minimum deg
ree of protection
of IP54. It is mounted on a 35-mm DIN rail according to
DIN EN 60715 TH35.
Safety
Precautions
Installation and commissioning of the device must be
performed only by authorized personnel .
Observe the country-specific regulations when installing
the device.
The electrical connection of the device is only allowed to
be made with the device isolated.
The wiring of the device must comply with the instructi-
ons in this user information, otherwise there is a risk that
the safety function will be lost.
Fig. 2 Installation/removal
system is switched off and switched on again.
The time-delay contacts are activated at the same time as
the non-time-delay contacts; however, when the emer-
gency stop button is pressed, the contacts are only deacti-
vated after the time set on the potentiometer (1 … 30s).
Electrical
Connection
A control transformer according to EN 61558-2-6 or a
power supply unit with electrical isolation from the mains
must be connected.
External fusing of the safety contacts (6A slow-blow or
8A quick-action or 10AgG) must be provided.
A maximum length of the control lines of 1000 meters
with a line cross section of 0.75 mm
2
must not be excee-
ded.
The line cross section must not exceed 2.5 mm
2
.
If the device does not function after commissioning, it
must be returned to the manufacturer unopened. Ope-
ning the device will void the warranty.
Fig. 3 Connections
(not for plug-in terminals)
nd = non-time delayed; d = time-delayed
Fig. 1 Block diagram: SR107AD (1nd/3d); SR108AD (2nd/2d); SR109AD(3nd/1d)
A1: Power supply
A2 : Power supply
S11: DC 24V control voltage
S10: Control line
S12: Control line
S13: Control line
S14: Control line
S21: Start, Control line
13-14: Safety contact 1 (nd)
23-24/27-28: Safety contact 2 (d / nd)
33-34/37-38: Safety contact 3 (d / nd)
47-48: Safety contact 4 (d)
SR107AD, SR108AD, SR109AD
User Information for SR107AD, SR108AD, SR109AD
Zobrazit stránku 0
1 2 3 4 5 6

Shrnutí obsahu

Strany 1 - SR107AD, SR108AD, SR109AD

1 Safety Technology & Innovation • Feedback loop for monitoring downstream contactors orexpansion modules • Cyclical monitoring of the output cont

Strany 2

2 Safety Technology & Innovation Depending on the application or the result of the risk assessment according to EN ISO 13849-1, the device must be

Strany 3

3 Safety Technology & Innovation Maintenance Device cannot be switched on again after an emergency stop: • Check whether the emergency stop circui

Strany 4

4 Safety Technology & Innovation Dimension Drawing 1149922,5SR107AD, SR108AD, SR109AD User Information for SR107AD, SR108AD, SR109AD ©2014 Omron

Strany 5 - Terms and Conditions of Sale

Terms and Conditions of Sale1. Offer; Acceptance. These terms and conditions (these "Terms") are deemedpart of all quotes, agreements, purc

Strany 6 - Printed on recycled paper

OMRON CANADA, INC. • HEAD OFFICEToronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron247.comOMRON ELECTRONICS DE MEXICO • HEAD OFFICEMéxico DF

Komentáře k této Příručce

Žádné komentáře